Search results for "Bone Plates"
showing 10 items of 27 documents
Reconstruction of large mandibular and surrounding soft-tissue defects using distraction with bone transport.
2012
Reconstruction of large bone and soft-tissue defects of the inferior third of the face is possible using various surgical techniques. Patients who require these procedures need to be in good general health, may have sequelae linked to donor sites, and require several interventions to achieve good aesthetic and functional results. The aim of this study was to report outcomes in patients with large mandibular and soft-tissue defects treated using osteogenic distraction with bone transport. Between 2001 and 2008, 14 patients had distraction with bone transport. Most patients were men (92.1%). The mean age was 43.1 years. The average mandibular bone reconstruction was 13.6 cm. The mean duration…
Complex radial head and neck fractures treated with modern locking plate fixation
2019
Background Internal fixation of complex radial head and neck (CRHN) fractures is difficult, and postoperative complications are common. This study evaluated elbow function and patient clinical status after internal fixation of CRHN fractures with modern locking plates. Methods We included 40 patients with 41 fractures (1 bilateral lesion). In 25 patients (61%), a concomitant injury was found. Patients were an average age of 46 years (range, 22-70 years). The mean follow-up time was 36 months (range, 2-70 months). Postoperative assessments included evaluation of range of motion, functional scores, and radiologic findings. We assessed fracture healing, surgical complications, revision surgery…
Predicting the failure in distal femur fractures.
2018
Abstract Introduction The incidence of nonunion after fractures of the distal femur is up to 6%. The distal femoral nonunion is a disabling disease that needs complex steps in his treatment. Aim of our study is to find predicting factors of non-unions. Materials and methods We retrospectively analyzed 116 cases of distal femoral fractures and 20 cases of non-unions. In both surgeries we analyzed: accuracy of reduction, stability of fixation, hardware used, residual medial or lateral bone defect, use of autologous or heterologous bone grafts. Results Malreduction, particularly axial defect, associated with unbalanced fixation, and a medial cortical bone defect of greater or lesser extent wer…
Open Reduction and Internal Fixation of Low Subcondylar Fractures of Mandible Through High Cervical Transmasseteric Anteroparotid Approach
2009
Purpose The aim of the present study was to evaluate the functional and radiologic results of low subcondylar fracture fixation with modus TCP plates (Medartis, Basel, Switzerland) using a high cervical transmasseteric anteroparotid approach. Materials and Methods A prospective study was designed, enrolling all minimum-aged 15-year-old echomorphology patients presenting with displaced low subcondylar fracture with occlusion disturbances during a 41-month period. All fractures were fixed with modus TCP plates using high cervical transmasseteric anteroparotid approach. All patients underwent immediate physiotherapy and a 6-week liquid and semiliquid feeding period. Clinical and radiologic exa…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Metastatic instability at the proximal end of the femur
1994
A retrospective study was performed of the surgical treatment of metastatic lesions of the proximal femur in 50 patients. In 25 consecutive cases a megaprosthesis was implanted; compound plate osteosynthesis was performed in another 25 consecutive patients. Indications for surgical treatment were pathological fractures or, for prophylactic treatment, lesions of the femoral cortex exceeding 2.5 cm in diameter or affecting half the diameter of the bone or more. In all patients capable of walking preoperatively mobility was regained. Immediate full weight-bearing stability was obtained in all patients. Group analysis showed that the functional rating of the hip joint was unchanged, i.e., good …
Transverse sacral fracture with intrapelvic intrusion of the lumbosacral spine: case report and review of the literature.
2000
Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable dis…
2012
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The si…
Efficacy of Zero-Profile Device versus Plate and Cage Implant for Treatment of Symptomatic Adjacent Segment Disease After Anterior Cervical Diskectom…
2018
Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior…
2009
Objectives: Two 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated. Methods: Eight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epic…